新資訊|2021年11月起,UL將會(huì)開始實(shí)行 UL8750的更新條文。

根據(jù)UL 10月資訊,2021年11月起,UL將會(huì)開始實(shí)行 UL8750 的更新條文。

以下為更新的詳細(xì)內(nèi)容:


01

SUPPLEMENT SE – REQUIREMENTS FOR CLASS P LED DRIVERS

SE5.3 A driver with field-wiring leads, field-wiring terminals, or push-in terminals shall be marked 

“Use only within an enclosure” or equivalent. 

The marking may be provided in an installation guide or equivalent accompanying document.

帶有現(xiàn)場(chǎng)接線、現(xiàn)場(chǎng)接端子, 推入式端子的 CLASS P LED 驅(qū)動(dòng)需要標(biāo)上“Use only within an enclosure”或相等標(biāo)簽。標(biāo)簽可以印產(chǎn)品或安裝說明書中。

02

6.7 Polymeric potting compound

6.7.3 Polymeric potting compound that can touch any part of the insulation system of a transformer shall be tested in accordance with Supplement SA

– Substitutions or Modification to an Electrical Insulation System in the Standard for Systems of Insulating Materials – General, UL 1446.

灌封膠如果接觸到變壓器絕緣系統(tǒng)任何部分, 就需要根據(jù) Supplement SA – Substitutions or Modification to an Electrical Insulation System in the Standard for Systems of Insulating Materials – General, UL 1446 進(jìn)行測(cè)試。

Exception No. 1: This test does not apply if the transformer is not used for the mitigation of the risk of electric shock or is not used to separate Class 2 circuits or LVLE circuits from hazardous circuits.

Exception No. 2: This test does not apply if the transformer insulation system already includes the potting.

Exception No. 3: This test does not apply if the insulation system is used up to the temperature permitted for class 105 (A) according to Table 8.1 of this standard.

Exception No. 4: This test does not apply for thermosetting potting compounds where the insulation system of a transformer utilizes a thermoset varnish which completely encloses the coil windings- preventing the potting compound from making contact with the winding wire insulation.

例外 1:如果變壓器不用于減輕電擊風(fēng)險(xiǎn)或不用于將 Class 2 電路或 LVLE 電路與危險(xiǎn)電路分開,則該測(cè)試不適用。

例外 2:如果變壓器絕緣系統(tǒng)已經(jīng)包括灌封膠,則該測(cè)試不適用。

例外 3:如果絕緣系統(tǒng)的使用溫度達(dá)到本標(biāo)準(zhǔn)表 8.1 規(guī)定的 105 (A) 級(jí)所允許的溫度,則該測(cè)試不適用。

例外 4:如果變壓器的絕緣系統(tǒng)使用熱固性清漆, 并完全包圍繞組線防止熱固性灌封膠與繞組線絕緣接觸,則該測(cè)試不適用。

03

7.2A.2 Grounding

A.2.7 When the path between the grounding connection means and the ground termination point in the product includes PWB traces, the construction is to be evaluated per the bonding conductor tests in 8.23.

當(dāng)接地連接裝置和接地端接點(diǎn)之間的路徑包括 PWB 走線時(shí),需要評(píng)估 8.23 bonding conductor tests。

04

SUPPLEMENT SF – LED EQUIPMENT WITH WIRED CONTROL CIRCUITS

LED 設(shè)備中用于控制功率,光輸出特性,操作或性能數(shù)據(jù)傳輸?shù)鹊目刂齐娐沸枰胶?SF 的要求。

Marking requirement

1. Identification of the terminals or lead wires for control circuits, Identification of the intended industry or proprietary protocols

2.Device wired control circuit marked ‘Class 2’

3. "CAUTION: More than one power supply present” or equivalent

4.“Notice: This control circuit is not isolated - see installation instructions” or equivalent

5. Installation instructions

Marking 要求

1.控制線路端子或電線識(shí)別,行業(yè)或?qū)S袇f(xié)定識(shí)別;

2."Class 2|如控制線路已評(píng)估 Class 2 或外接 Class 2 電源;

3.“CAUTION: More than one power supply present” 如控制線路是外接非 Class 2 電源;

4“Notice:This control circuit is not isolated - see installation instructions” 如控制電路是非隔離并滿足豁 SF3.1 免條款;

5.安裝說明。

希望以上信息能有助于廣大客戶更了解標(biāo)準(zhǔn)的要求。

如果希望了解更多有關(guān) UL8750 的更新條文,或是需要其它認(rèn)證相關(guān)資訊,歡迎隨時(shí)聯(lián)系我司咨詢了解。


深圳訊科商品檢驗(yàn)為第三方檢測(cè)機(jī)構(gòu),專業(yè)提供防塵防水測(cè)試,材料檢測(cè)中心,電子產(chǎn)品檢測(cè)中心,失效分析,電子元器件檢測(cè),CE認(rèn)證,FCC認(rèn)證,防火阻燃檢測(cè),質(zhì)檢報(bào)告,成分分析,ROHS認(rèn)證,reach認(rèn)證,可靠性測(cè)試,汽車零部件檢測(cè),MSDS報(bào)告,運(yùn)輸鑒定報(bào)告,高低溫測(cè)試,有害物質(zhì)檢測(cè),氣體腐蝕測(cè)試,金屬材料檢測(cè),質(zhì)量檢測(cè)報(bào)告,MTBF壽命測(cè)試,項(xiàng)目驗(yàn)收?qǐng)?bào)告,3C認(rèn)證;歡迎您的來(lái)電。